Penthouse, St Kilda
Five bathrooms — floors, walls and ceilings · 15 working days
For architects & designers
The Atriafloor Super Titanium system from Colorificio Atria, Sicily, installed by an Atria-certified team. Build-up, declared performance, substrate and wet-area requirements, and a specification clause, on one page.
Beautiful isn't enough. Architectural microcement has to perform as well as it looks.
01The system
Atria guarantees declared performance only when the complete cycle is used. We never substitute a layer.
| Layer | Product | Function | Application |
|---|---|---|---|
| Bond | Atriafloor Primer (tiled substrates) or Atriafloor Consolidating (concrete, screed, marble) | Two-component, water-based epoxy bonding primer | 100–150 g/m², 1 coat, roller |
| Build | Atriafloor Rasante One | Polymer-modified cementitious base. Levels, fills tile joints, gives structural strength | About 2 kg/m², 2 coats, steel trowel |
| Finish | Atria Super Titanium BC | Two-component, water-based polyurethane decorative finish with quartz, marble sand and Etna volcanic mineral | 1–1.2 kg/m², 2 coats, 0.8–1 mm, hand trowelled |
| Refine | Atriafloor Filler | Fine levelling layer before the topcoat | 1 coat · floors, and walls where a fully smooth finish is wanted |
| Protect | New Atriapol W Antibacterial | Two-component, water-based polyurethane topcoat. UV-resistant, non-yellowing, matt or gloss | 0.085–0.100 L/m² per coat, 2 coats |
In wet areas the system is installed over a waterproofing membrane. Microcement and its topcoat are a finish, not a membrane.
Atria products are distributed in Australia by Atria Australia.
02Declared performance
Manufacturer's declared values, tested to European standards. Data sheets are available on request.
| Layer | Property | Value | Standard |
|---|---|---|---|
| Rasante One | Compressive strength | 42 ± 2 MPa | EN 1015-11 |
| Rasante One | Flexural strength | 3.2 ± 2 MPa | EN 1015-11 |
| Rasante One | Adhesion | > 2.2–2.5 MPa | — |
| Super Titanium BC | Compressive strength | 32 ± 2 MPa at 28 days | EN 1015-11 |
| Super Titanium BC | Adhesion to concrete | > 3 MPa after 7 days | UNI 8298-1 |
| Super Titanium BC | Pull-off adhesion | > 2.5 N/mm² | ASTM D4541 |
| Super Titanium BC | Surface hardness | Shore D > 65 | DIN 53505 |
| New Atriapol W | Wet abrasion | > 10,000 cycles | DIN 53778 |
| New Atriapol W | Adhesion, rigid system under traffic | > 3.6 MPa | EN 1542 |
| New Atriapol W | Capillary water absorption | 0.052 kg/m²·h⁰·⁵ | EN 1062 |
| New Atriapol W | Surface hardness | Shore D > 60 | DIN 53505 |
| Atriafloor cycle | Reaction to fire | A2-s1-d0 | EN 13501-1 (LAPI report 1408.0DC0050/24) |
Colorificio Atria S.r.l., Partanna, Sicily. ISO 9001:2015 and ISO 14001:2015 certified. CE declarations of performance under EU Regulation 305/2011.
03Substrates
04Wet areas
05Program and curing
06Finish and colour
07Warranty, insurance and team
10-year product warranty from Atria Australia. 5-year workmanship warranty from MicroLux. Both transfer with the property. A check-up at 24 months.
$20M public liability. WorkCover. A SWMS issued for every project. Our own police-checked, White Card-certified installers, trained and certified in the Atria system. MicroLux Pty Ltd, ABN 28 273 430 986. Certificates of currency on request.
08Specification clause
Paste this into your finishes schedule and adjust the bracketed items.
Seamless microcement finish: Atriafloor Super Titanium system by Colorificio Atria S.r.l. (Italy), installed by MicroLux Finishes, Atria-certified installer. Build-up: Atriafloor Primer (tiled substrates) or Atriafloor Consolidating (concrete and screed substrates), 1 coat; Atriafloor Rasante One, 2 coats; Atria Super Titanium BC, 2 coats, 0.8–1.0 mm; Atriafloor Filler, 1 coat [floors / walls where a fully smooth finish is specified]; New Atriapol W Antibacterial, 2 coats, [matt / gloss]. Colour: [Atria Box True Cement reference / custom]. Texture: [smooth / subtle / Italian stamp]. Substrate to be sound, clean and moisture-tested before application; existing structural and control joints to be carried through the finish. In wet areas, install over a compliant waterproofing membrane to AS 3740. All layers from a single manufacturer; no substitution. Physical sample to be approved by the designer before commencement.
09Selected projects

Five bathrooms — floors, walls and ceilings · 15 working days

Two bathrooms and two powder rooms — floors and all walls, finished straight over the existing tiles · 9 working days

A bathroom and an ensuite finished straight over the existing tiles, plus the kitchen back wall and rangehood · 6 working days

Ground-floor living floor · 7 working days
10Request
Manufacturer data sheets, certificates of currency and the Atria colour chart are available on request.